Brand new INT-TSH2 and INT-TSG2
touchscreen keypads

Powerful processor, completely new interface,
swipe gestures support.
Meet the new level
of safety and building automation control.

CONFX hardware configurator

New version now available!

  • Even more useful functions
  • Easier and faster designing
  • New appearance

SMART BUILDING solutions

KNX modules

now available in SATEL's offer!

Find out more

SATEL on YouTube and Vimeo

Over 30 films and animations about us and our products

- subscribe to our channels and stay up to date!

 

GPRS-A

Universal GPRS monitoring module

GPRS-A is a universal monitoring module that can work as a stand-alone device or as part of intruder alarm systems as well as automation systems. The device is provided with a GSM telephone that supports data transmission in GPRS technology.

In the alarm systems, this module can be used to implement reporting, in conjunction with any alarm control panel. It connects to the control panel with the control panel dialer or appropriately configured outputs.

The device has 8 inputs, which can be set as digital (NO, NC) or analog. Those that work as analogue ones can be used in automation systems or to monitor a wide range of external devices, such as temperature, pressure and humidity sensors. Additionally, GPRS-A has a 1-Wire bus, to which up to 8 DS-T1 digital temperature sensors can be connected. The module can send measurement data using the MQTT, JSON, JSON/HTTP and MODBUS RTU open communication protocols, via GPRS. It is possible to create a server that will collect data from many modules. Gathered informations can be used for processing and visualization – e.g. to supervise environmental parameters prevailing in a group of cold stores, warehouses or production halls. This fits in with the concept of the so-called Internet of Things (IoT). In response to exceeding the preset threshold values of signals on analog inputs or from 1-Wire sensors, GPRS-A may respond by reporting such events to the monitoring station or send a notification to the indicated users. It allows to program an automatic reaction consisting in changing the status of selected outputs, e.g. by switching on the heating system due to a significant temperature drop.

The module offers notifications of up to 8 users, in several ways: by using SMS or PUSH messages, or via the CLIP service.

The device has 4 programmable outputs that can be remotely controlled using SMS, CLIP, GX CONTROL mobile application or GX Soft configuration program, as well as via IoT. GPRS-A can thus be used to remotely control the alarm system or other devices connected to the module.

Programming and configuration is performed using computer with the GX Soft program. Connection with the module can be local, via RS-232 (TTL) port, or remote, by connecting to the device via GPRS.

Remote update of the device (its firmware) is possible thanks to the interaction with the UpServ program.

  • conversion of telephone reporting to SMS / GPRS formats
  • sending notifications to max. 8 phone numbers
  • notification messaging: SMS/CLIP/PUSH
  • 8 programmable inputs (NO/NC/analog)
  • 1-Wire digital temperature sensor bus (up to 8 sensors)
  • possibility to configure response to exceeded threshold values at:
    • analog inputs
    • 1-Wire sensors
  • input for supervision of AC voltage presence
  • 4 outputs (2 relay, 2 OC type) controlled via SMS / CLIP (up to 10 000 numbers) / GX CONTROL / GX Soft / via IoT
  • IoT - support for MQTT, JSON, JSON/HTTP, MODBUS RTU open protocols via GPRS
  • possibility to check pre-paid account balance and send notification if it drops below required minimum
  • configuration by using GX Soft program:
    • locally via RS-232 (TTL)
    • remotely via GPRS
  • support for GX CONTROL mobile application
  • remote firmware update capability
  • possibility of connecting a dedicated power supply unit: APS-412, APS-612
EN-50136 SP 5
GPRS-A
The actual appearance of the products may differ from the presented images. Product descriptions are provided in the web service for information purposes only.

Documentation

general information manual
updated: 2021-12-15
2.26 MB
quick installer guide
updated: 2021-12-09
369 KB

Software

English
compiled: 2023-04-18
universal
compiled: 2021-12-10
multi-language
compiled: 2022-06-08
multi-language
compiled: 2023-09-25
multi-language
compiled: 2023-06-13

Certificates

EU declaration of conformity
updated: 2024-06-17
115 KB
EN-50136 SP 5
updated: 2024-09-20
2.34 MB

Technical Data

Environmental class
II
Number of OC outputs
2
Supply voltage
12 V DC
Number of inputs (zones)
8
Enclosure dimensions
83 x 65 x 23 mm
Operating temperature range
-10...+55 °C
Standby mode current consumption
80 mA
Max. current consumption
220 mA
Weight
110 g
Maximum humidity
93±3%
Number of OC relay outputs
2
Outputs O1…O2 (OC type)
50 mA / 12 V DC
Outputs O3…O4 (relay, NO type)
1000 mA / 30 V DC
Maximum allowable AC input voltage
25 V AC

Information materials

 © 1990-2021 SATEL sp. z o.o.
legal | privacy policy | Feedback | about site

The Satel.pl website uses cookies to enable Users' to take advantage of Satel.pl features as well as for statistical purposes. Unless you block cookies, you grant your consent for their use and storage in device memory. You must remember that you are able to manage cookies by means of your browser settings. Lack of adjustment of these settings means your consent for the Satel.pl website to use the cookies. See our Privacy Policy for more information.

Zamknij